Close

VESDA ASD & OSID by XTRALIS

VESDA ASD & OSID by XTRALIS There are 57 products.

VESDA ASD & OSID by XTRALIS

VESDA ASD & OSID by XTRALIS

The ultimate smoke detection solution by the world’s number 1 supplier of ASD systems

VESDA ASD & OSID by XTRALIS

VESDA ASD & OSID by XTRALIS

The ultimate smoke detection solution by the world’s number 1 supplier of ASD systems

VESDA ASD & OSID by XTRALIS

VESDA ASD & OSID by XTRALIS

The ultimate smoke detection solution by the world’s number 1 supplier of ASD systems

More

Subcategories

  • VESDA ASD Detectors
    Vesda ASD Detectors

    What is Very Early Warning Smoke Detection?

    VESDA by Xtralis very early warning aspirating smoke detection solutions with continuous air sampling provide the earliest possible warning of an impending fire hazard. VESDA aspirating smoke detectors buy the critical time needed to investigate an alarm and initiate an appropriate response to prevent injury, property damage or business disruption. VESDA detectors have multi-level warnings and a wide range of sensitivity that does not degrade or change over time, so even minute levels of smoke can be detected before a fire has time to escalate. In addition, VESDA systems are manufactured using targeted Six Sigma techniques and ISO 9000 standards and have been certified by regulatory bodies worldwide.

  • VESDA LCD Programmer & High Level Interfaces

    VESDA LCD PROGRAMMER

    FEATURES

    • User friendly menu system
    • Supports multiple languages
    • Single point access to entire VESDAnet system
    • Alarm and fault simulation
    • Shows wiring order
    • Locates communications failures
    • Password security
    • Hand held or remote mounting
    • Automatic Logoff when inactive
    • Backlit LCD screen

    up to 14 assigned users or Administrators with an individual 4 digit Personal identification Number (PiN), and one Distributor, can log onto a VESDAnet system under one of three levels of access which are password protected:

    • user (uSr) is only able to view parameters, check status, alarms and reset the system
    • administrator (adm) has access to most commands and programming parameters
    • distributor (dSt) is the topmost level and has unlimited access to all commands and parameters in the system
    • lost pIn numbers can be overcome by obtaining a once only pass number from your xtralis VESDA dealer

    VESDA HIGH LEVEL INTERFACE

    FEATURES

    • Direct access and monitoring of your entire VESDAnet system
    • Designed for small or large networks
    • VHX-0210 includes modem support for remote notification & interrogation
    • Seamless data transfer from your VESDAnet to your PC
    • Easily configured using Xtralis configuring and monitoring software packages
    • VESDA HLIs are recommended for monitoring only. They are not approved for use as a primary reporting device.

    The VESDA sliding Windows High Level interface (HLi) links your VESDAnet with PC software monitoring and configuring tools such as Xtralis VsM4 and Xtralis VsC. To configure and monitor devices on VESDAnet, your HLi must be connected to a VESDAnet socket card.

  • Filters & Spare Parts
    The VESDA in-Line Filter provides customers the ability to address a wide array of harsh environments with high levels of airborne contaminants in a simple and cost-effective manner.
    • Suitable for all Xtralis Aspirating Smoke Detectors
    • Improved detector longevity in applications with high levels of air-borne contamination
    • reduces maintenance intervals, thus reducing total cost of ownership
    • requires no additional pipe fittings thus reducing cost of installation
    • Improved aesthetics
    • Vertical or horizontal mounting
    • Compatible with metric (25mm OD) and imperial (1” OD) pipes eliminating the need for pipe adapters
  • Pipes and Fittings
  • 19" Rackmount Configurations
  • OSID Emitters & Imagers

    In its simplest configuration, OSID (Open-area Smoke Imaging Detection) uses one imager, a camera-like device with a wide field of view, and a wired or battery-powered emitter roughly aligned on the opposite wall within the protected area. The emitter sends both infrared and ultraviolet coded light signals to the imager. If the light reception is altered due to the presence of genuine smoke particles, the imager will go into alarm. The novel use of dual light frequencies in an open-path device enables OSID to discriminate between real smoke and other objects, including insects, steam, condensation and dust, thus drastically reducing false alarms.

    • Maximum detection range of 150 m (492 ft) for the OSI-10
    • Status LEDs for Fire, Trouble and Power
    • High false alarm immunity
    • Dust and intrusive solid object rejection
    • Easy alignment with large adjustment and viewing angles
    • No need for precise alignment
    • Tolerant of alignment drift
    • Automatic commisioning in under ten minutes
    • Simple DIP switch configuration
    • Dual wavelength LED-based smoke detection
    • Simple and easy maintenance requirements
    • Conventional alarm interface for straightforward fire system integration
    • Three selectable alarm thresholds
Showing 1 - 57 of 57 items
Showing 1 - 57 of 57 items
Close